Free Call Australia : 1 800 834 991

Related Products

Megger Resonating Inductor

MEGGER Resonating Inductor 
  • Expands the range of Capacitance and Dissipation Factor (Power Factor) Test Sets
  • Core gap gauge that displays position of inductor core & Hand-crank tuning wheel
  • Capable of tuning capacitances up to 1µF at 10 kV & Large wheels and handles for easy transport

Product Details

MEGGER Resonating Inductor

Expands the range of Capacitance and Dissipation Factor (Power Factor) Test Sets. Capable of tuning capacitances up to 1µF at 10 kV. Hand-crank tuning wheel. Core gap gauge that displays position of inductor core. Large wheels and handles for easy transport .

The Resonating Inductor is an accessory for use with the semi-automatic 12 kV Extended-Range Capacitance and Dissipation Factor Test Set, or the Automated Insulation Power Factor Test Set (DELTA-2000).

The Resonating Inductor is used to expand the capacitance range of these test sets and cannot be used with the standard 12 kV Capacitance and Dissipation Factor Test Set.

The Resonating Inductor is connected in parallel with the internal power supply of the test set. A manual tuning wheel on the Resonating Inductor varies the inductance to tune the parallel circuit for minimum load current.

When used with the semi-automatic 12 kV Extended-Range Capacitance and Dissipation Factor Test Set, or DELTA-2000, the Resonating Inductor will extend the short-time rating of the power supply from 200 mA to 4 A. This capacity is suitable for testing capacitance loads of up to 1 µF at 10 kV.

OMICRON CP RC Resonance Circuit for GIS Tester For HV testing OMICRON’s CPC 100 + CP RC are directly connected to the voltage transformer of the GIS, forming a resonance circuit. This rei...
MEGGER CB-100 Low Voltage Capacitance Lightweight and portable, 100-Hz test frequency & 30-V output voltage . Designed for testing in the laboratory, shop or substation, Model CB-100 i...
MEGGER DELTA4000 Series 12 kV Insulation Diagnostic System Automatic and manual operation. Accurate and repeatable measurement results with high noise suppression. Lightweight, rugged two...
MEGGER DELTA 2000 10-kV Automated Insulation Power Factor Test Set Extremely easy-to-use with no extensive hardware or software setup. Designed to work in high interference switchyards of...
WUHAN HUAYING HYGS Capacitance & Tan Delta Tester General introduction HYGS different frequency automatic dielectric loss tester is a high-precision instrument, which can be applied to...