Free Call Australia : 1 800 834 991

Related Products

Hioki 3169-20 Clamp-On Power HiTester

HIOKI 3169-20 Clamp-On Power HiTester New
  • Demand value and harmonic waveform measuring same voltage line 4-circuits simultaneously
  • Energy maintenance and control / Saving energy activities / Harmonic analysis
  • Power consumption measurement of specific device / equipment

Product Details

HIOKI 3169-20 Clamp-On Power HiTester • Monitor Power & Demand management at single-phase 4-circuits, three-phase 2-circuits, and harmonic analyse simultaneously. • Measure V, A, W, VA, Var, integration, PF, Hz • Measure wide ranges up to 5000 A • Built in Energy Meter for Energy audit application • PC card data storage 2GB • High-speed D/A output for analog graph recording (Model 3169-21) HIOKI 9625 Power Measurement Software for Post Analysis & Report Generation.

Measurement line & number of circuits:- Single-phase 2-wire (4 circuits), single-phase 3-wire (2 circuits), three-phase 3-wire (2 or 1 circuit), and three-phase 4-wire (1 circuit) Note: 50 or 60 Hz, and that share the same voltage line

Measurement range:-
Voltage range: 150/ 300/ 600 V AC

Current range: [when using the 9694] 500 mA, 1/ 5 A AC [when using the 9695-02] 500 mA, 1/ 5/ 10/ 50 A AC, [when using the 9660, 9695-03] 5/ 10/ 50/ 100 A AC [when using the 9661] 5/ 10/ 50/ 100/ 500 A AC [when using the 9669] 100/ 500/ 1 kA AC [when using the 9667] 500/ 5 kA AC

Power range: 75 W to 9 MW (Depends on combination of voltage and current range)

Measurement method:- Digital sampling, PLL synchronization or 50/60 Hz fixed clock

Basic accuracy:- Active power: ±0.2% rdg. ±0.1% f.s. + clamp-on sensor accuracy (at 45 to 66 Hz)

Display refresh rate:- Active power: ±0.2% rdg. ±0.1% f.s. + clamp-on sensor accuracy (at 45 to 66 Hz)

Display refresh rate:- 2 times /sec (except when using a PC card while accessing the internal memory, or when performing RS-232C communications)

Data save interval:- Standard interval: 1/ 2/ 5/ 10/ 15/ 30 seconds, or 1/ 2/ 5/ 10/ 15/ 30/ 60 minutes

Frequency characteristics:- Fundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45- to 66-Hz fundamental waveform)

Other functions:- Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, ±5 V DC f.s.)

Power requirements:- 100 to 240 V AC, 50/60 Hz, 30 VA max

Dimensions, mass:- 210 mm (8.27 in) W × 160 mm (6.30 in) H × 60 mm (2.36 in) D, 1.2 kg (42.3 oz)

Supplied accessories:- Voltage cord set 9438-53 ×1 (1 cord each of black, red, yellow, and blue), Power cord ×1, Instruction manual × 1, Quick start manual × 1, CD-R ×1 (RS-232C interface operating manuals), Input cord label ×1, Connection cable 9441 ×1 (for the 3169-21 only)

Product Description

HIOKI 3169-20 Clamp-On Power HiTester is the best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The 3169 is clamp on power meters designed to measure demand and harmonics, which are important for energy management, as well as basic electrical parameters such as voltage, current, power, power factor, and integrated power (watthours).

HIOKI PRO 9624-50 PQA-HiView Support data analyze with easy operation. When analyzing measurement data (binary) on the PC with the PW3198, please use PQA-HiVIEW PRO 9624-50 version 2.0 ...
ELSPEC G4500 BLACKBOX Portable Power Quality Analyzer. Power Quality in High Definition. Built on the same innovative technology as the BLACKBOX fixed Power Quality Meter (PQA), the ELSPEC G...
PITE TECH 3531 Power Quality Analyzer PITE TECH 3531 is 3p/3w and 3p/4w testing and analyzing device for the quality of power grid. It provides multiple analyzing for electric harmonic, v...
HIOKI 3169 Clamp On Power HiTester portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision...
ELSPEC BLACKBOX Firmware Release. Class A: Extended support per latest 61000-4-30 Class A revision. Many new parameters, averaged intervals, and more! Device Configuration FILE: Based on X...