Home omicron oms 600 fixed installed system
OMICRON OMS 600 Fixed-Installed SystemThe OMS 600 is a fixed installed system for continuous partial discharge (PD) monitoring. The online PD monitoring system consists of three or four coupling capacitors (3 phases + neutral). A short coaxial cable connects each coupling capacitor to the channel acquisition unit, which is linked by a fiber optic cable to the server. The OMS 600 can easily be extended to monitor a high number of high-voltage machines.The high sensitivity of this permanently-installed monitoring system is based on advanced technology. Partial discharge sources are separated by measuring synchronously at each channel and by using methods like 3PARD (3-Phase Amplitude Relation Diagram) and 3CFRD (3-Center Frequency Relation Diagram).Key features• Synchronous multi-channel PD data acquisition• Advanced technology like 3PARD and 3CFRD for PD source separation• Denoising using several gating methods (amplitude-, phase-, dynamic-, frequency-, channel-gating)• Optical isolation between partial discharge acquisition unit and server• High capacitance of coupling capacitors (up to 2.2 nF)Applications• Continuous monitoring of high-voltage assets• Permanent monitoring of PD phenomena at stator isolations of rotating machines