Free Call Australia : 1 800 834 991

Related Products

HV Diagnostics HVA 60 VLF/DC Hipots

HV Diagnostics HVA 60 VLF/DC Hipots 
  • User friendly software for immediate, professional detailed reporting and setup
  • Power supply immunity and independence
  • RMS Metering of Current and Voltage

Product Details

HV Diagnostics HVA 60 VLF/DC Hipots

The HVA60 VLF /DC high voltage test instrument is the instrument of choice when customers require a single instrument that can test the full range of Medium Voltage cables available – that is 35kV rated cables and below. This very popular, single piece instrument is widely used on long 35/33kV cable systems found in electrical utilities, wind and solar farms, etc. The HVA60’s portable design has a total weight equivalent to just one piece of many two piece VLF 60kV units available on the market. In addition, setting up the HVA60 instrument is simple with no cumbersome interconnects between various modules that make up a typical two-piece design.

Having both VLF AC and DC outputs, the HVA60 is not simply a high voltage instrument for testing MV cables, the unit can also be used for testing Vacuum bottles, cable jackets/sheaths, rotating machines, transformers, switchgear, etc. Test reports are downloaded to the instrument’s internal memory or to a USB flash drive.

As with all HVA units, fully automatic test sequences, digital RMS metering, and integrated storage of test results make the HVA60 a top seller.

FEATURES

• Test your 35kV below MV cable systems.
• Single Piece Design
• Weighs only 126 lbs / 57kg
• Perform tests fully automatically
• Real time oscilloscope display
• Insulation Resistance & Cap. measurement
• RMS Metering of Current and Voltage
• Output Frequency optimization
• Internal Storage of Test Reports
• Download to PC and / or USB flash drive
• Unlimited duty cycle
• Bright backlit LCD display
• Power supply immunity and independence
• Low maintenance, oil-free design
• HVA Control Center – User friendly software for immediate, professional detailed reporting and setup

OUTPUT MODES

• VLF 44kVrms / 62kVpk output
• DC ±60kV
• VLF Sinewave / Squarewave & DC outputs
• Cable Jacket / Sheath testing
• Vacuum bottle testing
• Fault Conditioning / Fault Trip
• Load independent output waveform

SAFETY

• Remote interlock “kill switch” and HV status indication
• Short circuit detection
• Local Emergency off button
• 12kV power frequency voltage feedback protection
• Flashover voltage detection
• Integrated internal discharge of DUT

KILOVOLT PRUEFTECHNIK KPG 38kV VLF & 50kV DC Portable Cable Test Set NEUMANN KPG 38kV VLF & 50kV DC Portable Cable Test Set Manufactured by Neumann Elektrotechnik GmbH Germany. The porta...
HIGH VOLTAGE VLF-34E Very Low Frequency AC Hipot The VLF-34E is a new generation VLF AC hipot that uses a solid state design with microprocessor controls. It meets the requirements of app...
KILOVOLT PRUEFTECHNIK KPG 20kV VLF Cable Test Set The portable cable test set KPG 20kV VLF is used for testing of medium voltage cables with extruded insulation (XLPE-, PE-, EPR-insulatio...
KILOVOLT PRUEFTECHNIK KPG 38kV VLF & 50kV DC Portable Cable Test Set NEUMANN KPG 38kV VLF & 50kV DC Portable Cable Test Set Manufactured by Neumann Elektrotechnik GmbH Germany. The porta...
KILOVOLT PRUEFTECHNIK KPG 50kV Cable Test Set The devices series KPG 50-120kV have been designed as Cable Test Sets for DC voltage testing of Medium Voltage Power Cables. There are 4 d...